How good is the measurement system? (measurement system analysis, gauge R&R)
In brief
How much of the measured spread comes from the measurement system, and how much from the parts themselves? For this every person (operator) measures every part several times. The analysis of variance splits the spread into repeatability (same device, same person), reproducibility (different operators) and the differences between the parts.
When
- Every part is measured by every person at least twice, and each combination of part and person has the same number of measurements (balanced).
- It becomes meaningful with about 10 parts, 3 operators and 2 to 3 repetitions. The parts should cover the whole range that the procedure is later to measure.
How it works in Statable
- Provide data with one measurement column and two grouping columns (part and operator).
- Run the card "Do groups differ?" with the measurement column and the two groupings (two-way analysis of variance). Under the result open the section "Measurement system analysis (gauge R&R)".
- Under "Which grouping names the parts?" choose the right one. The result appears at once.
Reading the result
- The table "Breakdown of the spread" gives for each source the variance, its share of the variance (%), the standard deviation and its share of the spread (%): measurement system overall (R&R), repeatability (device), reproducibility (operators), differences between the parts and total spread.
- The sentence "The measurement system makes up … % of the total spread" rates by the usual rule of thumb: below 10% good, 10 to 30% conditionally usable, above 30% not usable.
- The number of distinct groups of parts (ndc) should be at least 5 (rule of thumb).
- Interaction operators × parts: if it is not conspicuous (p above 0.25) Statable includes it in the error; otherwise it stays in the model. It can mean that operators measure some parts differently from others.
What is often misunderstood
The spread of the parts here does not stand for production but for the choice of parts. Anyone who measures only similar parts gets a poor share for the measurement system although it may be good.
Reporting the result
Report: the design of the study (number of parts, operators and repetitions), the method (crossed study, analysis-of-variance method), whether the operator × part interaction stayed in the model, then the share of the measurement system (R&R) in the total spread, split into repeatability and reproducibility, and the number of distinct categories (ndc). The rating (below 10% good, 10 to 30% conditional, above 30% not usable; ndc at least 5) comes from the AIAG manual (Measurement Systems Analysis Reference Manual, 4th ed. 2010) and is a rule of thumb. Also: the unit of the measure and the tolerance, if the share of the tolerance is given.
Gauge R&R (crossed study, analysis-of-variance method): … parts, … operators, … measurements per part and operator. The operator × part interaction was [not] conspicuous (p = …) and was [pooled into the error/kept in the model]. The measurement system accounted for … % of the total spread (repeatability … %, reproducibility … %); the number of distinct categories was ndc = ….
For specialists
Crossed study with the analysis of variance method: σ²_rep = MS_error; σ²_interaction = max(0, (MS_PxO - MS_error) / r); σ²_operators = max(0, (MS_O - MS_PxO) / (p r)); σ²_parts = max(0, (MS_P - MS_PxO) / (o r)). ndc = ⌊√2 · σ_parts / σ_R&R⌋. Reference values: R SixSigma::ss.rr with alphaLim = 0.25.
Sources
Automotive Industry Action Group (2010). Measurement systems analysis reference manual (4th ed.). AIAG. Burdick, R. K., Borror, C. M. & Montgomery, D. C. (2003). A review of methods for measurement systems capability analysis. Journal of Quality Technology, 35, 342-354.