Does the procedure measure the same thing when repeated? (test-retest reliability, ICC, test-retest correlation)
In brief
Test-retest reliability says how similar the values of the same people stay when the same procedure is repeated later. For this Statable shows the intraclass correlation coefficient (ICC) and, with exactly two measurements, the test-retest correlation r_tt (Pearson correlation of the two measurements).
When
- A questionnaire or test was given twice to the same people although the trait should not change.
- The interval has to fit: too short and memory helps; too long and the trait has really changed. That is a decision of the study, not of the calculation.
In SPSS
In SPSS this is "Analyze, Scale, Reliability Analysis" with the model "Two-Way Mixed" or "Two-Way Random" and the statistic "Intraclass correlation coefficient"; the correlation is under "Analyze, Correlate, Bivariate". Statable calculates the ICC with its own code in the browser (ICC(2,1) and ICC(3,1) agree with R irr::icc and SPSS).
How it works in Statable
- "New analysis", card "Do ratings agree?", choose the column of the first and the one of the second measurement (two number columns).
- Leave the choice at "The same (absolute agreement)": that is the recommendation for test-retest reliability (Koo and Li 2016).
- The result has the sentence on the ICC and in it "Test-retest correlation r_tt = …". The table "All four ICC measures" shows ICC(2,1) and ICC(3,1) with intervals.
Reading the result
- ICC(2,1), absolute agreement: the reliability of a single measurement. It drops when the second measurement is on average higher or lower (practice effect). Classification according to Koo and Li (2016): below .50 poor, up to .75 moderate, up to .90 good, above that excellent. The whole interval matters, not only the estimate.
- ICC(3,1), consistency: a constant difference between the measurements (everyone improves by two points) does no harm. The value is never below that of absolute agreement.
- Test-retest correlation r_tt: Pearson correlation of the two measurements. It sees only whether the order of the people stays the same, not whether the values stay the same. The Reliable Change Index (RCI; Jacobson and Truax 1991) puts in a reliability of the procedure, often r_tt or alpha. Anyone who wants shifts between the measurements to count uses the ICC for absolute agreement instead: a smaller value and so a stricter RCI.
What is often misunderstood
- A high correlation does not mean that the values stayed the same: if everyone rises by ten points, r_tt stays at 1. That is why for the question "How stable is the value?" the ICC for absolute agreement is preferable (Koo and Li 2016): r_tt overlooks shifts.
- A low test-retest reliability can be due to the trait (it really changes), not only to the procedure.
Reporting the result
Report: the interval between the measurements, the sample size, the ICC form (for example ICC(2,1), absolute agreement) with 95% interval, and the test-retest correlation.
The test-retest reliability of [procedure] was tested in N = … people with an interval of … [days/weeks]. The ICC for absolute agreement was ICC(2,1) = …, 95% CI […; …]; the test-retest correlation was r_tt = ….
For specialists
ICC after McGraw and Wong (1996) in the two-way model; absolute agreement corresponds to R irr::icc with model = "twoway", type = "agreement", consistency to type = "consistency", each with unit = "single". r_tt is cor(t1, t2) by Pearson over people with both values.