statable Statistics for study and research

Is this conspicuous value really unusual? (outlier tests: Grubbs, generalized ESD, Dixon)

In brief

An outlier test asks whether a conspicuous value would be unusual with a normal distribution. It does not say whether the value is an error. The case stays in the data; Statable removes nothing. Anyone who wants to exclude cases uses the data assistant "Selection" for that (reversible).

When

How it works in Statable

  1. Run the card "How is something distributed?" with the number column. Under the result open the section "More options: check for outliers" and switch on "Check for outliers".
  2. With several number columns choose "Which column?". Then the test (Grubbs, generalized ESD or Dixon; unsuitable ones are greyed out) and the level (0.10, 0.05 or 0.01).
  3. With the Grubbs test the direction: two-sided (default), only too high or only too low values. One-sided is only allowed if the direction was fixed before looking at the data. With the ESD test "Look for at most this many outliers".

Reading the result

What is often misunderstood

Reporting the result

Report: the test (Grubbs, generalized ESD or Dixon), the level, whether it was one- or two-sided (one-sided only with a reason fixed before looking at the data), the test statistic with the critical value, the row of the reported value and, most important, what was done with it. Also: the results with and without the value side by side and, for ESD, the maximum number of outliers fixed in advance. The tests assume roughly normally distributed values (Grubbs 1969, Technometrics 11, 1-21).

An outlier test by [Grubbs/Dixon/generalized ESD] (α = …, [two-sided]) examined the value … (row …): [G/r₁₀/R_i] = …, critical value = …; the value [stood out/did not stand out]. It stayed in the data. Results with and without it: M = … (SD = …) versus M = … (SD = …).

For specialists

The critical values of Grubbs and ESD follow from the t distribution, without a table. The critical value of the Dixon test r10 for n = 3 to 10 is calculated exactly (two-dimensional integration, confirmed by simulation) and differs in the third digit from the copied table in Rorabacher. Tietjen-Moore and the modified z score are not built.

Sources

Grubbs, F. E. (1950). Sample criteria for testing outlying observations. Annals of Mathematical Statistics, 21, 27-58. Rosner, B. (1983). Percentage points for a generalized ESD many-outlier procedure. Technometrics, 25, 165-172. Dixon, W. J. (1950). Analysis of extreme values. Annals of Mathematical Statistics, 21, 488-506. Rorabacher, D. B. (1991). Statistical treatment for rejection of deviant values. Analytical Chemistry, 63, 139-146.

Related

Open in Statable